Read LG LB-D2460HL Service Manual online
–32–
Possible Trouble 2
: The indoor fan does not operate.
NO
NO
Is it the HOT
START mode?
Is IC01M operated
normally?
Check the fan motor
and connector.
(CN-MOTOR)
and connector.
(CN-MOTOR)
YES
Is the each Relay
any problem?
YES
NO
YES
It is normal operation.
Exchange IC01M
Exchange Relay
NO
YES
YES
YES
Is the LCD operated
normally?
Is the terminal of wired
Remocon T2 DC12V
Is the pin 31, 32 of
Micom DC 5V
Change the wired Remocon.
Check the wired Remocon
PCB and DC 12V pattern.
PCB and DC 12V pattern.
NO
NO
Check the parts of
communication.
communication.
Connector CN-Remo, and
terminals of wired
Remocon exactly.
terminals of wired
Remocon exactly.
Possible Trouble 3
: Wired remote controller does not operate.