Read JBL GTO 755.6 (serv.man3) EMC - CB Certificate online
Page 9 of 11
File No.: E042R-020
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: Sub Output R-CH
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
33.20
35.30
25.20
1.50
0.94
37.74
27.64
45.12
35.12
49.40
29.30
-
0.58
1.02
30.90
-
45.72
35.72
59.20
35.50
24.60
0.07
1.20
36.77
25.87
46.08
36.08
80.80
27.80
-
-0.50
1.20
28.50
-
46.88
36.88
- Coupling Location
: Plus(+) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.40
37.10
26.60
1.39
0.97
39.46
28.96
45.05
35.05
55.40
37.50
26.90
0.10
1.20
38.80
28.20
45.94
35.94
61.10
36.10
24.70
-0.39
1.20
36.91
25.51
46.15
36.15
72.40
33.20
-
-0.30
1.25
34.15
-
46.57
36.57
- Coupling Location
: Minus(-) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
32.40
38.10
27.40
1.45
0.95
40.50
29.80
45.09
35.09
50.50
34.90
23.20
0.30
1.02
36.22
24.52
45.76
35.76
68.10
35.60
24.80
0.08
1.20
36.88
26.08
46.41
36.41
Click on the first or last page to see other GTO 755.6 (serv.man3) service manuals if exist.