Read JBL GTO 755.6 (serv.man3) EMC - CB Certificate online
Page 10 of 11
File No.: E042R-020
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: Remote Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
34.10
36.10
25.10
1.55
0.92
38.57
27.57
45.15
35.15
54.80
33.80
22.20
0.28
1.19
35.27
23.67
45.92
35.92
60.80
35.30
23.90
-0.39
1.20
36.11
24.71
46.14
36.14
71.30
32.70
-
-0.30
1.23
33.63
-
46.53
36.53
- Coupling Location
: Remote Level Control Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
36.20
31.00
21.10
3.63
0.97
35.60
25.70
45.23
35.23
56.50
35.50
24.60
0.09
1.20
36.79
25.89
45.98
35.98
65.40
36.70
25.20
0.10
1.20
38.00
26.50
46.31
36.31
71.00
29.40
-
-0.30
1.22
30.32
-
46.52
36.52
Note: Q.P : Quasi-peak, AVE : Average
Q.P Limit [dB(pW)]: Freq.(MHz) / 27 + 43.89
A.V Limit [dB(pw)]: Freq.(MHz) / 27 + 33.89
In case that Quasi-Peak values are under the Average limit, Average data are not recorded.
Tested by: Eung-Chan, Kim / Test Engineer