Page 9 of 10
File No.: E042R-018
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: Minus(-) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.10
36.40
25.40
1.31
1.00
38.71
27.71
45.00
35.00
54.30
35.70
25.10
0.29
1.17
37.16
26.56
45.90
35.90
70.20
32.80
22.40
-0.30
1.20
33.70
23.30
46.49
36.49
81.80
29.90
-
-0.50
1.20
30.60
-
46.92
36.92
- Coupling Location
: Remote Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.10
37.30
26.10
1.31
1.00
39.61
28.41
45.00
35.00
41.60
30.40
19.60
1.28
1.20
32.88
22.08
45.43
35.43
52.70
31.60
20.40
0.29
1.11
33.00
21.80
45.84
35.84
58.60
29.70
-
0.07
1.20
30.97
-
46.06
36.06
Note: Q.P : Quasi-peak, AVE : Average
Q.P Limit [dB(pW)]: Freq.(MHz) / 27 + 43.89
A.V Limit [dB(pw)]: Freq.(MHz) / 27 + 33.89
In case that Quasi-Peak values are under the Average limit, Average data are not recorded.
Tested by: Eung-Chan, Kim / Test Engineer