Read JBL GTO 75.4 (serv.man13) EMC - CB Certificate online
Page 8 of 10
File No.: E042R-018
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: Rear Output L-CH
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.90
38.00
25.30
1.42
0.96
40.38
27.68
45.07
35.07
38.90
28.70
-
3.49
1.13
33.32
-
45.33
35.33
56.70
32.70
-
0.09
1.20
33.99
-
45.99
35.99
68.90
28.10
-
0.08
1.20
29.38
-
46.44
36.44
- Coupling Location
: Rear Output R-CH
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.80
37.00
27.60
1.35
0.98
39.33
29.93
45.03
35.03
47.00
30.50
-
0.59
1.12
32.21
-
45.63
35.63
53.20
32.40
-
0.29
1.13
33.82
-
45.86
35.86
57.50
31.70
-
0.08
1.20
32.98
-
46.02
36.02
- Coupling Location
: Aux Output Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
31.60
31.50
20.20
1.40
0.97
33.87
22.57
45.06
35.06
37.30
31.60
20.90
3.57
1.04
36.21
25.51
45.27
35.27
54.30
27.70
-
0.29
1.17
29.16
-
45.90
35.90
- Coupling Location
: Plus(+) Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.10
36.90
26.00
1.31
1.00
39.21
28.31
45.00
35.00
37.00
35.10
24.60
3.59
1.02
39.71
29.21
45.26
35.26
52.70
34.90
24.20
0.29
1.11
36.30
25.60
45.84
35.84
58.10
34.80
24.10
0.08
1.20
36.08
25.38
46.04
36.04
65.60
34.60
23.80
0.10
1.20
35.90
25.10
46.32
36.32
78.90
30.90
-
-0.40
1.22
31.72
-
46.81
36.81
Click on the first or last page to see other GTO 75.4 (serv.man13) service manuals if exist.