File No.: E042R-014
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-007 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
- Coupling Location
: Remote Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.10
29.40
-
1.31
1.00
31.71
-
45.00
35.00
41.60
26.80
-
1.28
1.20
29.28
-
45.43
35.43
56.70
32.40
-
0.09
1.20
33.69
-
45.99
35.99
67.00
31.10
-
0.09
1.20
32.39
-
46.37
36.37
- Coupling Location
: Remote Level Control Cable
Freq. Reading[dBuV] Insert
Cable Total[dB(pW)]
LIMIT[dB(pW)]
[MHz] [Q.P] [AVE] Loss Loss [Q.P] [AVE]
[Q.P]
[AVE]
30.30
35.80
26.30
1.32
0.99
38.11
28.61
45.01
35.01
47.30
33.90
24.20
0.59
1.11
35.60
25.90
45.64
35.64
58.40
30.20
-
0.07
1.20
31.47
-
46.05
36.05
Note: Q.P : Quasi-peak, AVE : Average
Q.P Limit [dB(pW)]: Freq.(MHz) / 27 + 43.89
A.V Limit [dB(pw)]: Freq.(MHz) / 27 + 33.89
In case that Quasi-Peak values are under the Average limit, Average data are not recorded.
Tested by: Eung-Chan, Kim / Test Engineer