Read JBL GTO 301.1 (serv.man13) EMC - CB Certificate online
Page 4 of 17
File No.: E042R-015
It should not be reproduced except in full, without the written approval of ONETECH.
EMC-008 (Rev.0)
HEAD OFFICE
: #505 SK APT. Factory 223-28, Sangdaewon 1 Dong, Jungwon-Gu, Seongnam-City, Gyunggi-Do, 462-121, Korea
(TEL:
+82-31-746-8500, FAX: +82-31-746-8700
)
EMC Testing Dept :
426-1
Daessangryung-Ri, Chowol-Myun, Gwangju-City, Gyunggi-Do 464-860 Korea. (TEL: +82-31-765-8289, FAX: +82-31-766-2904)
ONETECH
Testing & Evaluation Lab.
1. APPLICANT AND MANUFACTURER INFORMATION
-. Applicant
: Harman Consumer Group.
-. Address
: New York 250 Crossways Park West Woodbury, NY 11797, USA
-. Manufacturer
: Chunglam Digital Co., Ltd.
-. Address
: #453-4, Yongduri, Gongdo-Eup, Ansung-Si, Kyunggi-Do, 456-821, Korea
-. Name of contact
: Mr. Jin-Ho, Jung/ Supervisor
-. Telephone No.
: +82-31-656-7650
-. Fax No.
: +82-31-656-9688
2. TEST SUMMARY
2.1 Test standards and results
STANDARDS RESULTS
Electrostatic Discharge Immunity
Met Criterion A / PASS
Radiated RF E-Field (900MHz +/- 5MHz)
Met Criterion A / PASS
EN 55 020: 1994 + A11: 96 + A12: 99
+ A13: 99 + A14: 99
Electrical Fast Transient/Burst Immunity
Met Criterion A / PASS
2.2 Additions, deviations, exclusions from standards
No additions, deviations or exclusions have been made from standard.
2.3 Purpose of the test
To determine whether the equipment under test fulfills the EMC-immunity requirements of the standards stated in section
2.1.
2.4 Criterion description
Criterion Description
A
No loss of performance or function.
B
The apparatus shall continue operate as intended after test. No degradation of performance or loss
of function is allowed below a performance level specified by the manufacturer, when the
apparatus is used as intended.
C
Temporary loss of function or performance, which is provided the function, is self-recoverable or
can be restored by the operation of the controls.