Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 22 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
5.1.8
Touch currents to telecommunication networks and
cable distribution systems and from
telecommunication networks
cable distribution systems and from
telecommunication networks
Not connected to a
telecommunication network or
cable distribution systems
telecommunication network or
cable distribution systems
N/A
5.1.8.1
Limitation of the touch current to a
telecommunication network or to a cable
distribution system
telecommunication network or to a cable
distribution system
N/A
Supply
voltage (V) ................................................ :
⎯
Measured touch current (mA) .............................. :
⎯
Max.
allowed
touch
current (mA) ......................... :
⎯
5.1.8.2
Summation of touch currents from
telecommunication networks
telecommunication networks
N/A
a) EUT with earthed telecommunication ports ..... :
N/A
b) EUT whose telecommunication ports have no
reference to protective earth
reference to protective earth
N/A
5.2 Electric
strength
Evaluated in approved apdater
N/A
5.2.1 General
N/A
5.2.2 Test
procedure
N/A
5.3
Abnormal operating and fault conditions
P
5.3.1
Protection against overload and abnormal
operation
operation
(see appended table 5.3)
P
5.3.2 Motors
N/A
5.3.3 Transformers
N/A
5.3.4 Functional
insulation
.............................................
:
Functional insulation complies
with the requirements (c)
with the requirements (c)
P
5.3.5 Electromechanical
components
The equipment does not have
any electromechanical
components
any electromechanical
components
N/A
5.3.6 Audio
amplifiers in ITE ......................................... :
P
5.3.7
Simulation of faults
(see appended table 5.3)
P
5.3.8 Unattended
equipment
N/A
5.3.9
Compliance criteria for abnormal operating and
fault conditions
fault conditions
See below
P
5.3.9.1
During the tests
No fire, emission of molten
metal or deformation of
enclosure was noted during
the tests
metal or deformation of
enclosure was noted during
the tests
P
5.3.9.2
After the tests
Neither fire occurred nor
molten metal emitted. No
need to do electric strength
test.
molten metal emitted. No
need to do electric strength
test.
P
6
CONNECTION TO TELECOMMUNICATION NETWORKS
N/A
Click on the first or last page to see other VOYAGER (serv.man5) service manuals if exist.