Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 20 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
4.4.5.2
Protection for users
N/A
Use of symbol or warning …………………………:
N/A
4.4.5.3
Protection for service persons
N/A
Use of symbol or warning …………………………:
N/A
4.5 Thermal
requirements
P
4.5.1
General
See appended table 4.5.1
P
4.5.2
Temperature tests
(see appended table 4.5)
P
Normal load condition per Annex L ...................... :
⎯
4.5.3
Temperature limits for materials
(see appended table 4.5)
P
4.5.4
Touch temperature limits
(see appended table 4.5)
P
4.5.5 Resistance
to
abnormal heat ............................... :
N/A
4.6 Openings
in
enclosures
P
4.6.1
Top and side openings
No any opening
P
Dimensions (mm) ................................................. :
⎯
4.6.2
Bottoms of fire enclosures
No any opening
P
Construction of the bottomm, dimensions (mm) .. :
⎯
4.6.3
Doors or covers in fire enclosures
No doors or covers.
N/A
4.6.4
Openings in transportable equipment
Not transportable equipment.
N/A
4.6.4.1
Constructional design measures
N/A
Dimensions (mm) ................................................. :
⎯
4.6.4.2
Evaluation measures for larger openings
N/A
4.6.4.3
Use of metallized parts
N/A
4.6.5
Adhesives for constructional purposes
No barrier secured by
adhesive inside enclosure.
adhesive inside enclosure.
N/A
Conditioning temperature (
°C), time (weeks) ........ :
⎯
4.7
Resistance to fire
P
4.7.1
Reducing the risk of ignition and spread of flame
Method 1: Selection and
application of components
and materials that minimize
the possibility of ignition and
spread of flame
application of components
and materials that minimize
the possibility of ignition and
spread of flame
P
Method 1, selection and application of components
wiring and materials
wiring and materials
Selection and application of
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
components, wiring and
materials, which reduce the
possibility of ignition and
spread of flame by the use of
fire enclosure (see appended
critical component table)
P
Click on the first or last page to see other VOYAGER (serv.man5) service manuals if exist.