Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 13 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.10
Clearances, creepage distances and distances through insulation
Class III device, no hazardous voltage inside; also evaluated in approved adapter
P
2.10.1
General
See below.
P
2.10.1.1 Frequency
.............................................................
:
N/A
2.10.1.2 Pollution
degrees
.................................................. : Pollution Degree 2.
P
2.10.1.3
Reduced values for functional insulation
The functional insulation
complied with clause 5.3.4
complied with clause 5.3.4
P
2.10.1.4 Intervening
unconnected conductive parts
N/A
2.10.1.5
Insulation with varying dimensions
N/A
2.10.1.6 Special
separation
requirements
N/A
2.10.1.7
Insulation in circuits generating starting pulses
N/A
2.10.2
Determination of working voltage
N/A
2.10.2.1 General
N/A
2.10.2.2
RMS working voltage
N/A
2.10.2.3
Peak working voltage
N/A
2.10.3 Clearances
P
2.10.3.1 General
P
2.10.3.2
Mains transient voltages
N/A
a) AC mains supply ............................................... :
N/A
b) Earthed d.c. mains supplies ............................. :
N/A
c) Unearthed d.c. mains supplies ......................... :
N/A
d) Battery operation .............................................. :
N/A
2.10.3.3
Clearances in primary circuits
N/A
2.10.3.4
Clearances in secondary circuits
Only the functional insulation
in secondary circuits complied
with clause 5.3.4
in secondary circuits complied
with clause 5.3.4
P
2.10.3.5
Clearances in circuits having starting pulses
N/A
2.10.3.6
Transients from a.c. mains supply ........................ :
N/A
2.10.3.7
Transients from d.c. mains supply ........................ :
N/A
2.10.3.8
Transients from telecommunication networks and
cable distribution systems ..................................... :
cable distribution systems ..................................... :
N/A
2.10.3.9
Measurement of transient voltage levels
—
a) Transients from a mains supply
N/A
For an a.c. mains supply ....................................... :
N/A
For a d.c. mains supply ......................................... :
N/A
b) Transients from a telecommunication network :
N/A
2.10.4 Creepage
distances
N/A
2.10.4.1 General
N/A
2.10.4.2
Material group and comparative tracking index
N/A
Click on the first or last page to see other VOYAGER (serv.man5) service manuals if exist.