VOYAGER (serv.man5) - JBL Audio EMC - CB Certificate (repair manual). Page 13

Read JBL VOYAGER (serv.man5) EMC - CB Certificate online

Report No.: SF201300640 
Page 13 of 68
EN 60950-1 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
 
2.10 
Clearances, creepage distances and distances through insulation 
Class III device, no hazardous voltage inside; also evaluated in approved adapter 
2.10.1 
General  
See below.  
2.10.1.1 Frequency 
 
............................................................. 
:  
N/A 
2.10.1.2 Pollution 
degrees 
 
.................................................. : Pollution Degree 2. 
2.10.1.3 
Reduced values for functional insulation 
The functional insulation 
complied with clause 5.3.4 
2.10.1.4 Intervening 
unconnected conductive parts 
 
N/A 
2.10.1.5 
Insulation with varying dimensions 
 
N/A 
2.10.1.6 Special 
separation 
requirements 
 
N/A 
2.10.1.7 
Insulation in circuits generating starting pulses 
 
N/A 
2.10.2 
Determination of working voltage 
 
N/A 
2.10.2.1 General 
 
N/A 
2.10.2.2 
RMS working voltage 
 
N/A 
2.10.2.3 
Peak working voltage 
 
N/A 
2.10.3 Clearances 
 
2.10.3.1 General 
 
2.10.3.2 
Mains transient voltages 
 
N/A 
 
a) AC mains supply  ............................................... :  
N/A 
 
b) Earthed d.c. mains supplies  ............................. :  
N/A 
 
c) Unearthed d.c. mains supplies  ......................... :  
N/A 
 
d) Battery operation  .............................................. :  
N/A 
2.10.3.3 
Clearances in primary circuits 
 
N/A 
2.10.3.4 
Clearances in secondary circuits 
Only the functional insulation 
in secondary circuits complied 
with clause 5.3.4 
2.10.3.5 
Clearances in circuits having starting pulses 
 
N/A 
2.10.3.6 
Transients from a.c. mains supply  ........................ :  
N/A 
2.10.3.7 
Transients from d.c. mains supply  ........................ :  
N/A 
2.10.3.8 
Transients from telecommunication networks and 
cable distribution systems  ..................................... :
 N/A 
2.10.3.9 
Measurement of transient voltage levels 
 
— 
 
a) Transients from a mains supply 
 
N/A 
 
For an a.c. mains supply  ....................................... :  
N/A 
 
For a d.c. mains supply  ......................................... :  
N/A 
 
b) Transients from a telecommunication network : 
 
N/A 
2.10.4 Creepage 
distances 
 
N/A 
2.10.4.1 General 
 
N/A 
2.10.4.2 
Material group and comparative tracking index 
 
N/A 
Page of 68