Read JBL VOYAGER (serv.man5) EMC - CB Certificate online
Report No.: SF201300640
Page 9 of 68
EN 60950-1
Clause
Requirement + Test
Result - Remark
Verdict
2.1.1.1
Access to energized parts
N/A
Test by inspection ................................................. :
N/A
Test with test finger (Figure 2A) ............................ :
N/A
Test with test pin (Figure 2B) ................................ :
N/A
Test with test probe (Figure 2C) ........................... : No TNV circuits within the
equipment.
N/A
2.1.1.2
Battery compartments
TNV circuits within the
equipment
equipment
N/A
2.1.1.3
Access to ELV wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N/A
Working voltage (Vpeak or Vrms); minimum
distance through insulation (mm)
distance through insulation (mm)
⎯
2.1.1.4
Access to hazardous voltage circuit wiring
No internal wiring at ELV
accessible to the operator.
accessible to the operator.
N/A
2.1.1.5 Energy
hazards ..................................................... :
N/A
2.1.1.6 Manual
controls
No conductive shafts of
operating knobs, handles,
levers and the like
operating knobs, handles,
levers and the like
N/A
2.1.1.7
Discharge of capacitors in equipment
N/A
Measured voltage (V); time-constant (s) ................ :
⎯
2.1.1.8 Energy
hazards – d.c. mains supply
Not connected to DC mains
supply.
supply.
N/A
a) Capacitor connected to the d.c. mains supply .. :
N/A
N/A
2.1.1.9 Audio
amplifiers ..................................................... :
P
2.1.2
Protection in service access areas
No bare parts operating at
hazardous voltage in a
service access area
hazardous voltage in a
service access area
N/A
2.1.3
Protection in restricted access locations
The equipment is not limited
to be used in restricted
access locations.
to be used in restricted
access locations.
N/A
2.2 SELV
circuits
P
2.2.1 General
requirements
P
2.2.2
Voltages under normal conditions (V) ................... : Between any conductor of the
SELV circuits, 42.4Vpeak or
60Vd.c. is not exceeded.
60Vd.c. is not exceeded.
P
2.2.3
Voltages under fault conditions (V) ....................... : Under fault conditions
voltages never exceed 71Vpk
and 120Vdc and do not
exceed 42.4Vpk or 60Vdc for
more than 0.2 second
and 120Vdc and do not
exceed 42.4Vpk or 60Vdc for
more than 0.2 second
P