Read JBL SUB Brochure online
Page 34 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Object/part No.
Manufacturer/
trademark
Type/model
Technical data
Standard
Mark(s) of
conformity1)
Shrinking
tubing
tubing
Changyuan
Electronics
(Shenzhen) Co.,
Ltd.
Electronics
(Shenzhen) Co.,
Ltd.
CB-1000
600 Vac, 125
°
C
Applicable
parts of IEC
60065, UL
224
UL recognized
Alt.
Dongguan
Quantai Industrial
Co., Ltd.
Quantai Industrial
Co., Ltd.
T-2
600 Vac, 125
°
C
Applicable
parts of IEC
60065, UL
224
UL recognized
Varistor RV1
(after mains
fuse)
Thinking
Electronic
Industrial Co.,
Ltd.
TVR10471
470 V, 500 A
IEC 61051-2
VDE
Thermistor TR1 Thinking
Electronic
Industrial Co.,
Ltd.
SCK2R55A
5 A
IEC 60065
Tested with
appliance
appliance
Fuse in stand
by power
supply
by power
supply
various
various
T250mA, 250 V
IEC60127
VDE
Amplifier
Plastic Cover
Plastic Cover
Chi Mei
Corporation
Corporation
PA-765 (ABS)
Min.: 3 mm, V-0,
85
o
C
Applicable
parts of IEC
60065, UL 94
UL recognized
Supplementary information:
1) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
1) An asterisk indicates a mark which assures the agreed level of surveillance
2) A separately approved power cord that incorporates plugs which complies with the special national
requirements shall be provided with this apparatus when be marketed in the specified countries.