Read JBL SUB Brochure online
Page 33 of 36
Report No.: TP11100216-ST
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Component
Manufacturer/
trademark
trademark
Type/model Value/rating
Standard
Approval/
reference
reference
1)
Optocoupler
(OP1)
Cosmo Electronic
Corporation
K1010
Dti
≥
0,5mm,
external Cr. = 8 mm,
internal Cr. = 5.3 mm
DIN VDE 0884
IEC 60950
VDE
Alt.
Cosmo Electronic
Corporation
KPC817
Dti
≥
0,5mm,
external Cr. = 8 mm,
internal Cr. = 5.3 mm
DIN VDE 0884
IEC 60950
VDE
Transformer
(TR1)
Xin Wnag
Electronics
Industry Co., Ltd.
KB1157-
11486
Class 130
IEC 60065
Tested with
appliance
appliance
-Magnet wire
Hoi Luen
Electrical MFR
Co., Ltd.
XUEW
Alt.
E&B Technology
Co., Ltd.
E&B-XXXB
Rated min. 130°C,
Primary winding:
N1:
Ф
0.2mm X 1P x 61Ts
N4:
Ф
0.2 mm X 1P x
61Ts
N5:
Ф
0.2 mm X 1P x
10Ts
Secondary winding:
N2:
N2:
Ф
0.25mm x 1P X
8Ts
N2:
Ф
0.25mm x 1P X
8Ts
IEC 60065
Tested with
appliance
appliance
- Insulation tape Jing Yahua
Pressure
Sensitive Glue
Co., Ltd.
Sensitive Glue
Co., Ltd.
CT
130
°
C
IEC 60065
Tested with
appliance
appliance
-Bobbin
Chang Chun
Plastics Co., Ltd.
Plastics Co., Ltd.
T375J
V-0, 150
o
C,
Min. 0,75 mm thick
IEC 60065
Tested with
appliance
appliance
-Varnish
Hang Cheung
Petrochemical Ltd.
Petrochemical Ltd.
8562
155
°
C
IEC 60065
Tested with
appliance
appliance
Click on the first or last page to see other SUB service manuals if exist.