Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
d) Energy of discharge not exceeding 350 mJ
N/A
9.1.1.2
Test with test finger and test probe
P
9.1.2
No hazardous live shafts of knobs, handles or levers
N/A
9.1.3
Ventilation holes and other holes tested by means of
4 mm x 100 mm test pin
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test pin
(10 N); test probe D of IEC 61032
P
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
P
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm test
pin (10 N); test probe C of IEC 61032
N/A
9.1.6
No shock hazard due to stored charge on withdrawal
of the mains plug; voltage (V) after 2 s ………………:
0V
P
If C is not greater than 0,1
μF no test needed
N/A
9.1.7
Resistance to external forces
a) Test probe 11 of IEC 61032 for 10 s (50 N)
P
b) Test hook of fig. 4 for 10 s (20 N)
P
c) 30 mm diameter test tool for 5 s (100 or 250 N)
N/A
9.2
No hazard after removing a cover by hand
N/A
10
Insulation requirements
10.1
Insulation resistance (M
Ω) at least 2 MΩmin. after
surge test for basic and 4 M
Ωmin. for reinforced
insulation ………………………………………………..:
N/A
10.2
Humidity treatment 48 h or 120 h …………………….: 48 and 120h. See also page 52.
P
10.3
Insulation resistance and dielectric strength between
mains terminals
P
Insulation Resistance and dielectric strength across
BASIC or SUPPLEMENTARY insulation (Class 1)
N/A
Insulation resistance and dielectric strength across
REINFORCED insulation (Class II)
P
11
Fault conditions
11.1
No shock hazard under fault condition
P
11.2
Heating under fault condition
P
Flames extinguish within 10 seconds
P
No hazard from softening solder
P
Soldered terminations not used as protective
mechanism
P