Read JBL SUB 200 EMC - CB Certificate online
Page 8 of 54
Report No.: 1009939
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
P
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Mains wires are double
insulated
insulated
P
8.10
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
No secondary wire can come in
to contact with bare live parts.
to contact with bare live parts.
P
8.11
Detaching of wires
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No risk of any wire becoming
detached.
detached.
N/A
Vibration test carried out ……………………………:
No, no need. See above.
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
P
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
P
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
In Standby transformer TR1.
P
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
8.19.1
Disconnect device
Mains plug
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
P
8.21
Bridging components comply with clause 14
C15
P
8.22
Non-separable thin sheet material
N/A
9
Electric shock hazard under normal operating conditions
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
P
9.1.1.1
a) Open circuit voltages
P
b) Touch current measured from terminal devices
using the network in annex D ………………………:
using the network in annex D ………………………:
See Table 9
P
c) Discharge not exceeding 45
μC
N/A