Read JBL SUB 180 EMC - CB Certificate online
page 16 of 28
Ref.No.: 410586
IEC 60065
Cl.
Requirement - Test
Result - Remark
Verdict
TRF No.: I60065__C
16.4
Flexible cords used for connection between
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
equipment have adequate cross-sectional areas to
avoid temperature rise under normal and fault
conditions
N
16.5
Adequate strain relief on external flexible cords
P
Not possible to push cord back into equipment
P
Strain relief device unlikely to damage flexible cord
P
For mains cords of Class
Ι equipment, hazardous
live conductors become taut before earth
conductor
conductor
N
16.6
Apertures for external flexible cord: no risk of
damage to the cord during assembly or movement
in use
damage to the cord during assembly or movement
in use
P
16.7
Transportable musical instruments and amplifiers
fitted with detachable cord set with appliance inlet
to IEC 60320-1
fitted with detachable cord set with appliance inlet
to IEC 60320-1
N
Transportable musical instruments and amplifiers
fitted with detachable cord sets or with means of
stowage to protect the cord
fitted with detachable cord sets or with means of
stowage to protect the cord
N
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to Table 12:
- screws into metal: 5 times
N
- screws into non-metallic material: 10 times
3.6x15.5mm, 1.2N
4.1x19.8mm, 1.2N
4.1x19.8mm, 1.2N
P
17.2
Correct introduction into female threads in non-
metallic material
metallic material
P
17.3
Cover fixing screws: captive
N
Non-captive fixing screws: no hazard when
replaced by a screw whose length is 10 times its
diameter
replaced by a screw whose length is 10 times its
diameter
P
17.4
No loosening of conductive parts carrying a current
> 0.2 A
> 0.2 A
N
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0.2 A
other than ceramic for connections carrying a
current > 0.2 A
N
17.6
Stranded conductors of flexible supply cords
carrying a current > 0.2 A with screw terminals not
consolidated by solder
carrying a current > 0.2 A with screw terminals not
consolidated by solder
N
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
adequate strength and their positioning is
unambiguous
N