SUB 150P (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL SUB 150P (serv.man6) EMC - CB Certificate online

 
Page 13 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
13.7 
Enclosed, enveloped or hermetically sealed parts not 
conductively connected to the mains, clearances and 
creepage distances as in table 12  
 N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 N/A 
 
14 Components 
 
14.1 Resistors 
 
 
N/A 
 
a) Resistors between hazardous live parts and 
accessible metal parts  
 N/A 
 
b) Resistors, other than between hazardous live 
parts and accessible parts  
 N/A 
 
Resistors separately approved ……………………….:  
N/A 
14.2 
Capacitors and RC units  
 
 
Capacitors separately approved ……………………:  Yes 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition ...: 
Y1: C03 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition ...: 
X2: C19, C06 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2 ......................: 
 N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, where 
short-circuit current exceeds 0,2 A: compliance with 
IEC60384-1, 4.38 category B or better  ..................: 
 N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 4.38 
category B or better  ................................................: 
 N/A 
 
Shielded by a barrier acc. to 20.1.4/ table 21 or 
metal ........................................................................: 
 N/A 
14.3 
Inductors and windings  
 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4  
 P 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type ...............................: 
Transtec 
TT0900901830-E 
Huizhou GP Wiring Technology
 
TD-230-0300A+C 
TD-230-0300A+A 
Standby transformer TR1: 
 DW KB1157-11486 
 
Transformers and inductors separately approved .: 
No 
N/A 
14.3.2 General 
 
 
 
Insulation material complies with clause 20.1.4  
 
Page of 84
Display