Read JBL SUB 150P (serv.man6) EMC - CB Certificate online
Page 13 of 58
Report No.: 1009950
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065J
13.7
Enclosed, enveloped or hermetically sealed parts not
conductively connected to the mains, clearances and
creepage distances as in table 12
conductively connected to the mains, clearances and
creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
requirements of 8.8
N/A
14 Components
14.1 Resistors
N/A
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ……………………….:
N/A
14.2
Capacitors and RC units
P
Capacitors separately approved ……………………: Yes
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...:
Y1: C03
P
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...:
X2: C19, C06
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
connected to the mains: tests for X2 ......................:
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³, where
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ..................:
short-circuit current exceeds 0,2 A: compliance with
IEC60384-1, 4.38 category B or better ..................:
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1, 4.38
category B or better ................................................:
N/A
Shielded by a barrier acc. to 20.1.4/ table 21 or
metal ........................................................................:
metal ........................................................................:
N/A
14.3
Inductors and windings
P
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
manufacturer's name and type ...............................:
Transtec
TT0900901830-E
Huizhou GP Wiring Technology
TD-230-0300A+C
TD-230-0300A+A
TD-230-0300A+A
Standby transformer TR1:
DW KB1157-11486
DW KB1157-11486
P
Transformers and inductors separately approved .:
No
N/A
14.3.2 General
P
Insulation material complies with clause 20.1.4
P
Click on the first or last page to see other SUB 150P (serv.man6) service manuals if exist.