Page 8 of 58 
Report No.: 1009950 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
 
TRF No. IEC60065J 
Constructional requirements with regard to the protection against electric shock
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare  
PCB P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc.  
Tools are required 
N/A 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material  
 P 
8.4 
No risk of electric shock from accessible parts or 
from parts rendered accessible following the removal 
of a cover which can be removed by hand  
 P 
8.5 
Class I equipment  
 
N/A 
 
Basic insulation between hazardous live parts and 
earthed accessible parts  
 N/A 
 
Resistors bridging basic insulation complying with 
14.1 a)  
 N/A 
 
Capacitors bridging basic insulation complying with 
14.2.1 a)  
 N/A 
 
Protective earthing terminal  
 
N/A 
8.6 
Class II equipment and Class II constructions within 
Class I equipment  
 P 
 
Double or reinforced insulation between hazardous 
live parts and accessible parts  
 P 
 
Components bridging double or reinforced insulation 
complying with 14.1 a) or 14.3  
Main transformer and standby 
transformer TR1 
 
Basic insulation bridged by components complying 
with 14.3.4.3.  
 N/A 
 
Basic and supplementary insulation each being 
bridged by a capacitor complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with 2 
capacitors in series complying with 14.2.1 a)  
 N/A 
 
Double or reinforced insulation being bridged with a 
single capacitor complying with 14.2.1 b)  
C03 P 
8.7 
This clause is void  
 
 
8.8 
Basic or supplementary insulation > 0,4 mm (mm) ...: Primary wires are double 
insulated. Tubing on standby 
PCB. 
 
Reinforced insulation > 0,4 mm (mm) ……………….:  
N/A 
 
Thin sheet insulation (excluding non-separable thin 
sheet insulation. See 8.22)  
Tape in Main transformer and 
TIW in TR1 