Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 39 of 48
5.8.4 TEST RESULTS
EUT
JBL Wireless Speaker
Mode Number
JBL SPARK
Test date
2013-05-03
Voltage Supply
AC 230V/50HZ
Test Engineer
Liang
environment
Tem:21℃ Hum:54 %100kPa
Test mode:
1. Test the EUT in mode 1:BT
2. Test the EUT in mode 2:Standby
2. Test the EUT in mode 2:Standby
Voltage
(% Reduction)
Duration
(Period)
Angle
Required
Passing
Performance
Actual
performance
Test
Result
Voltage
dips
30% 25 0°
Criterion
B A* PASS
Voltage
dips
100% 0.5 0°
Criterion
B A* PASS
Voltage
dips
100% 1 0°
Criterion
B A* PASS
Voltage
interruptions
100% 250 0°
Criterion
C C* PASS
Note: A*: EUT is working on intended use operation, no abnormal phenomenon was observed.
C*: There was the EUT shut up and need restart by the operator.
Click on the first or last page to see other SPARK (serv.man7) service manuals if exist.