SPARK (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 39

Read JBL SPARK (serv.man7) EMC - CB Certificate online

Report No.:  EM201300221-2                Application No.:  ZJ00028648                       Page 39 of 48 
 
 
5.8.4 TEST RESULTS 
EUT 
JBL Wireless Speaker 
Mode Number 
JBL SPARK 
Test date 
2013-05-03 
Voltage Supply 
AC 230V/50HZ 
Test Engineer 
Liang 
environment 
Tem:21℃ Hum:54 %100kPa 
Test mode: 
1. Test the EUT in mode 1:BT  
2. Test the EUT in mode 2:Standby 
 
Voltage 
( Reduction) 
Duration 
(Period) 
Angle 
Required 
Passing 
Performance 
Actual 
performance
Test 
Result 
Voltage 
dips 
30% 25  0° 
Criterion 
B A* PASS 
Voltage 
dips 
100% 0.5  0° 
Criterion 
B A*  PASS 
Voltage 
dips 
100% 1  0° 
Criterion 
B A* PASS 
Voltage 
interruptions 
100% 250  0° 
Criterion 
C  C*  PASS 
Note: A*: EUT is working on intended use operation, no abnormal phenomenon was observed. 
C*: There was the EUT shut up and need restart by the operator. 
Page of 48
Display

Click on the first or last page to see other SPARK (serv.man7) service manuals if exist.