Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 34 of 48
5.6.4 TEST RESULTS
EUT
JBL Wireless Speaker
Mode Number
JBL SPARK
Test date
2013-05-03
Voltage Supply
AC 230V/50Hz
Test Engineer
Liang
environment
Tem:21℃ Hum:54 %100kPa
Test mode:
1. Test the EUT in mode 1:BT
2. Test the EUT in mode 2:Standby
2. Test the EUT in mode 2:Standby
Test Point Polarity
Test
Level
(kV)
Phase
Performanc
e
Criterion
Actual
performanc
e
Result
(P/F)
L - N
+/- 1 0° B
A
*
PASS
+/- 1 90° B
A
*
PASS
+/- 1
180° B
A
*
PASS
+/- 1
270° B
A
*
PASS
A*: EUT is working on intended use operation, no abnormal phenomenon was observed.