Read JBL SPARK (serv.man7) EMC - CB Certificate online
Report No.: EM201300221-2 Application No.: ZJ00028648 Page 27 of 48
5.3.4 TEST RESULTS
EUT
JBL Wireless Speaker
Mode Number
JBL SPARK
Test date
2013-05-03
Voltage Supply
AC 230V/50Hz
Test Engineer
Liang
environment
Tem:21 Hum:54 %100kPa
Test mode:
1. Test the EUT in mode 1:BT
2. Test the EUT in mode 2:Standby
2. Test the EUT in mode 2:Standby
Discharge point
Discharge
voltage
C-Conduct
A-Air
Required
Passing
Performance
Actual
performance
Result
Gap
±8 kV
A
Criterion B
Criterion A*
PASS
Button
±8 kV
A
Criterion B
Criterion A*
PASS
Nonmetallic
±8 kV
A
Criterion B
Criterion A*
PASS
Vertical coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
Horizontal coupling
plane
±4 kV
C
Criterion B
Criterion A*
PASS
A*: EUT is working on intended use operation, no abnormal phenomena was observed.