Read JBL SPARK (serv.man10) EMC - CB Certificate online
Report No.: EM201300221-6
Application No.: ZJ00028648 Page 8 of 19
4. EMISSION TEST
4.1 RADIATED ELECTROMAGNETIC DISTURBANCE MEASUREMENT
4.1.1 LIMITS
Frequency (MHz)
Quasi-peak(dBµV/m)
30 ~ 88
40
88~216 43.5
216 ~ 960
46
Above 960
54
NOTE: (1) The lower limit shall apply at the transition frequencies.
4.1.2 TEST PROCEDURE
Procedure of Preliminary Test
According to ANSI C63.10:2009, a calibrated, linearly polarized antenna shall be positioned
at the specified distance from the periphery of the EUT. The specified distance is the distance
between the horizontal projection onto the ground plane of the closest periphery of the EUT
and the projection onto the ground plane of the center of the axis of the elements of the
receiving antenna.
at the specified distance from the periphery of the EUT. The specified distance is the distance
between the horizontal projection onto the ground plane of the closest periphery of the EUT
and the projection onto the ground plane of the center of the axis of the elements of the
receiving antenna.
Measurements shall be made with the antenna positioned in both the horizontal and vertical
planes of polarization. The measurement antenna shall be varied in height above the reference
ground plane to obtain the maximum signal strength. Unless otherwise specified, the
measurement distance shall be 3 m. At any measurement distance, the antenna height shall be
varied from 1 m to 4 m. These height scans apply for both horizontal and vertical
polarizations, except that for vertical polarization, the minimum height of the center of the
antenna shall be increased so that the lowest point of the bottom of the lowest antenna
element clears the site reference ground plane by at least 25 cm. For a tuned dipole, the
minimum heights as measured from the center of the antenna are those specified in the NSA
measurement requirements.
planes of polarization. The measurement antenna shall be varied in height above the reference
ground plane to obtain the maximum signal strength. Unless otherwise specified, the
measurement distance shall be 3 m. At any measurement distance, the antenna height shall be
varied from 1 m to 4 m. These height scans apply for both horizontal and vertical
polarizations, except that for vertical polarization, the minimum height of the center of the
antenna shall be increased so that the lowest point of the bottom of the lowest antenna
element clears the site reference ground plane by at least 25 cm. For a tuned dipole, the
minimum heights as measured from the center of the antenna are those specified in the NSA
measurement requirements.
For tabletop systems, cables or wires should be manipulated within the range of likely
arrangements. For floor-standing equipment, the cables or wires should be located in the
same manner as the user would install them and no further manipulation is made. For
combination EUTs, the tabletop and floor-standing portions of the EUT shall follow the
procedures for their respective setups and cable manipulation.
arrangements. For floor-standing equipment, the cables or wires should be located in the
same manner as the user would install them and no further manipulation is made. For
combination EUTs, the tabletop and floor-standing portions of the EUT shall follow the
procedures for their respective setups and cable manipulation.
Table-top equipment is placed on a non-conductive set-up table with height 0, 8 m ± 0, 01 m,
ANSI C63.10:2009 specifies the method to determine the impact of the non-conductive
set-up table on test results. If the manner of cable installation is not known, or if it changes
with each installation, cables or wires for floor-standing equipment shall be manipulated to
the extent possible to produce the maximum level of emissions. For each mode of operation
required to be tested, the frequency spectrum shall be monitored. Variations in antenna height
between 1 m and 4 m, antenna polarization, EUT azimuth, and cable or wire placement shall
be explored to produce the emission that has the highest amplitude relative to the limit.
ANSI C63.10:2009 specifies the method to determine the impact of the non-conductive
set-up table on test results. If the manner of cable installation is not known, or if it changes
with each installation, cables or wires for floor-standing equipment shall be manipulated to
the extent possible to produce the maximum level of emissions. For each mode of operation
required to be tested, the frequency spectrum shall be monitored. Variations in antenna height
between 1 m and 4 m, antenna polarization, EUT azimuth, and cable or wire placement shall
be explored to produce the emission that has the highest amplitude relative to the limit.
Click on the first or last page to see other SPARK (serv.man10) service manuals if exist.