SOUNDFLY BT - JBL Audio EMC - CB Certificate (repair manual). Page 62

Read JBL SOUNDFLY BT EMC - CB Certificate online

 
ATTACHMENT 1  
Nation Differences 
( 23 / 28 ) 
Report No. : 12-1330-0046 
 
TRF No. IEC60065K 
 
 
 
 
Gas discharge t ubes complying w it h t he 
f ollow ing t est s may be connect ed t o bridge 
BASIC or REINFORCED INSULATION.  
 
Ten samples of  gas discharge t ubes isolat ing 
t he ac supply f rom exposed part s shall be 
subject ed t o t he varist or pulse t est s of  Clause 
14.12. Follow ing t he pulses, t he device shall 
be allow ed t o ret urn t o room t emperat ure. 
The dielect ric breakdow n volt age of  t he gas 
t ube shall not  decrease by more t han 50%  
and t he gas discharge t ube shall comply w it h 
t he elect ric st rengt h t est  of  Clause 10.3, w it h 
t he t est  volt age reduced t o t w ice t he mains 
volt age. 
15.1 
Plugs and sockets 
15.1.1 
(Convenience Recept acle Type) 
Add t he Follow ing Clause: 
A recept acle provided f or general purpose 
mains out put  shall comply w it h t he 
requirement s of  CSA St andard C22.2 No 42 
(dimensional requirement s are also specif ied 
in IEC 60906-2). The at t achment  plug cap 
shall be polarized t ype w hen t he apparat us is 
provided w it h a manually operat ed, MAINS 
connect ed single pole sw it ch f or apparat us 
on-of f  operat ion, a socket  screw shell 
lampholder, or a 15 or 20 A socket  out let .  
No socket  out let . 
 
N/A 
 
15.1.2 
(Audio Terminals
Add t he f ollow ing paragraph: 
Banana plugs shall be accept able.  
No banana plugs. 
 
N/A 
 
15.1.3 
Adapter output connectors 
Replace t he f irst  paragraph w it h t he f ollow ing:  
Terminals and connect ors used in out put  
circuit s of  supply apparat us, w hose out put  is 
not  a st andard nominal mains volt age 
according t o IEC 60038, Table 1, shall not  be 
compat ible w it h t hose specif ied f or household 
and similar general purposes, f or example 
t hose described in IEC 60083[1], IEC 60320, 
IEC 60884, IEC 60906 (part s 1, 2, and 3), 
and CSA C22.2 No 42. 
No mains out put . 
 
N/A 
 
15.2 
Provisions for protective earthing - Bond 
Impedance 
Replace t he t hird paragraph w it h t he 
f ollow ing: 
Eart hing connect ions shall comply w it h t he 
t est  requirement s of  CSA C22.2 No 0.4.  
 
N/A 
Page of 75