Read JBL SOUNDFLY BT EMC - CB Certificate online
ATTACHMENT 1
Nation Differences
( 22 / 28 )
Report No. : 12-1330-0046
TRF No. IEC60065K
CLEARANCES bet w een a loudspeaker voice
coil and adjacent conduct ive part s shall be
disregarded.
14.2
Capacitors and RC-units
14.2.1
(Y-Capacit ors)
Add t he f ollow ing paragraph:
Add t he f ollow ing paragraph:
As an alt ernat ive an isolat ing capacit or
complying w it h applicable requirement s of
CSA C22.2 No 1, shall be accept able f or
bridging BASIC or SUPPLEMENTARY
INSULATION.
complying w it h applicable requirement s of
CSA C22.2 No 1, shall be accept able f or
bridging BASIC or SUPPLEMENTARY
INSULATION.
P
14.2.2
(X-Capacit ors)
Add t he f ollow ing paragraph:
Add t he f ollow ing paragraph:
As an alt ernat ive an across-line capacit or
complying w it h applicable requirement s of
CSA C22.2 No 1, shall be accept able.
complying w it h applicable requirement s of
CSA C22.2 No 1, shall be accept able.
P
14.5.1.
2
2
Thermal releases
Add t he f ollow ing paragraph:
Add t he f ollow ing paragraph:
As an alt ernat ive a THERMAL LINK complying
w it h CSA C22.2 No 209 shall be accept able.
w it h CSA C22.2 No 209 shall be accept able.
Considered
P
14.5.2
Fuse-links and fuse holders
14.5.2.
1
1
Add t he f ollow ing paragraph:
As an alt ernat ive, a f use-link complying w it h
CSA C22.2 No 248.14 shall be accept able.
CSA C22.2 No 248.14 shall be accept able.
N/A
14.5.2.
4
4
Add t he f ollow ing paragraph:
As an alt ernat ive a Fuseholder Assembly
complying w it h CSA C22.2 No 39 shall be
accept able.
complying w it h CSA C22.2 No 39 shall be
accept able.
N/A
14.6
Switches
14.6.1
t o
14.6.5
t o
14.6.5
Add t he f ollow ing t o each of t he Clauses:
As an alt ernat ive, a TV-Rat ed Sw it ch
complying w it h CSA C22.2 No 1 -98, Cl 9
shall be accept able.
complying w it h CSA C22.2 No 1 -98, Cl 9
shall be accept able.
N/A
14.11
Optocouplers
Add t he f ollow ing paragraph:
Add t he f ollow ing paragraph:
As an alt ernat ive, an opt ocoupler complying
w it h CSA C22.2 No. 1 shall be accept able.
w it h CSA C22.2 No. 1 shall be accept able.
P
14.12
Surge suppression varistors
Add t he f ollow ing paragraph:
Add t he f ollow ing paragraph:
As an alt ernat ive, a varist or complying w it h
CSA C22.2 No. 1 shall be accept able.
CSA C22.2 No. 1 shall be accept able.
No varist or.
N/A
14.12A
Gas discharge tubes
Add New Clause 14.12A:
Add New Clause 14.12A:
No gas t ube.
N/A