SOUNDFLY BT - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL SOUNDFLY BT EMC - CB Certificate online

 
Page 15 of  38 
Report No. : 12-1330-0046 
 
IEC/EN 60065 
Clause 
Requirement + Test 
 Result - Remark 
Verdict 
 
TRF No. IEC60065K 
 
 
 
 
Creepage distances in accordance with 13.4  
Clearance measured 
according to annex E.   
Pollution degree 2 was 
considered. 
13.2 
Determination of working voltage  
The apparatus was connected 
to a 120 or 230V TN power 
system. 
13.3 
Clearances  
See below. 
13.3.1 
General  
(see appended table 13) 
13.3.2 
Circuits conductively connected to the mains comply 
with table 8 and, where applicable, table 9 ............. : 
(see appended table 13) 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10  
Accessible parts circuits 
verified by short-circuit tests 
according to 4.3.1. 
13.3.4 
Measurement of transient voltages  
Normal transient voltage 2500 
V considered (overvoltage 
category II for primary circuits). 
13.4 
Creepage distances  
(see appended table 13) 
 
Creepage distances greater than table 11 minimum 
values  
Considered. 
13.5 
Printed boards  
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10  
 
N/A 
13.5.2 
Type B coated printed circuit boards complying with 
IEC 60664‑ 3 (basic insulation only)  
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4  
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8  
 
N/A 
 
Temperature cycle test and dielectric strength test  
 
N/A 
 
500V test for transformers, magnetic coupler and 
similar devices, if insulation is relied upon for safety 
 
N/A 
13.7 
Enclosed, enveloped or hermetically sealed parts 
not conductively connected to the mains, clearances 
and creepage distances as in table 12  
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8  
 
N/A 
 
14 
Components 
Page of 75
Display