Read JBL SOUNDFLY BT EMC - CB Certificate online
Page 11 of 38
Report No. : 12-1330-0046
IEC/EN 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Double or reinforced insulation
provided between conductors
connected to the mains and
accessible parts.
provided between conductors
connected to the mains and
accessible parts.
P
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Double or reinforced insulation
provided between internal
hazardous live parts and
conductors connected to
accessible parts.
provided between internal
hazardous live parts and
conductors connected to
accessible parts.
P
8.11
Detaching of wires
Conductors with mechanical
securing.
No wire could be became
detached after the test below.
securing.
No wire could be became
detached after the test below.
P
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
No undue reduction of
creepage and clearance
distances below the values
specified in clause 13.
creepage and clearance
distances below the values
specified in clause 13.
P
Vibration test carried out ......................................... :
See subclause 12.1.2.
P
8.12
This clause is void
N/A
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
The internal wiring does not
touch hot parts or sharp edges,
which may damage its
insulation and cause hazards.
touch hot parts or sharp edges,
which may damage its
insulation and cause hazards.
P
8.16
Only special supply equipment can be used
The apparatus is supplied from
AC mains.
AC mains.
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
See below.
P
8.19.1
Disconnect device
The mains plug is used as the
disconnect device and see
also subclause 5.4.2.
disconnect device and see
also subclause 5.4.2.
P
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A