SCS 145 Sub - JBL Audio EMC - CB Certificate (repair manual). Page 9

Read JBL SCS 145 Sub EMC - CB Certificate online

 
 
page 5 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
HEATING UNDER NORMAL OPERATING CONDITIONS (See appended table) 
 
7.1 
Temperature rises not exceeding specified values, 
no operation of fuse links 
 P 
7.1.1 
Temperature rise of accessible parts 
 
7.1.2 
Temperature rise of parts providing electrical 
insulation 
 P 
7.1.3 
Temperature rise of parts acting as a support or as 
a mechanical barrier 
 P 
7.1.4 
Temperature rise of windings 
 
7.1.5 
Parts not subject to a limit under 7.1.1 to 7.1.4 
 
7.2 
Softening temperature of insulating material 
supporting parts conductively connected to the 
mains carrying a current > 0.2 A at least 150 ºC 
Mains fuse holder 
 
CONSTRUCTIONAL REQUIREMENTS WITH REGARD TO THE PROTECTION 
AGAINST ELECTRIC SHOCK 
 
8.1 
Conductive parts covered by lacquer, paper, 
untreated textile oxide films and beads etc. 
considered to be bare 
 P 
8.2 
No shock hazard when changing voltage setting 
device, fuse-links or handling drawers etc. 
 N 
8.3 
Insulation of hazardous live parts not provided by 
hygroscopic material 
Not used 
8.4 
No risk of electric shock following the removal of a 
cover which can be removed by hand 
  
8.5 
Class 
Ι equipment 
 
Basic insulation between hazardous live parts and 
earthed accessible parts 
 N 
 
Capacitors bridging basic insulation complying with 
14.2.1a 
 N 
 
Basic insulation bridged by components complying 
with 14.3.4.3 
 N 
 
Class 
ΙΙ equipment and Class ΙΙ constructions 
within Class 
Ι equipment 
 N 
Page of 46