SCS 145 Sub - JBL Audio EMC - CB Certificate (repair manual). Page 20

Read JBL SCS 145 Sub EMC - CB Certificate online

 
 
page 16 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
16 EXTERNAL 
FLEXIBLE 
CORDS 
 
16.1 
Mains cords sheathed type, complying with 
IEC 60227 for PVC or IEC 60245 for synthetic 
rubber cords  .......................................................... :
PVC  
 
Non-detachable cords for Class 
Ι have 
green/yellow core for protective earth 
 N 
16.2 
Mains cords conductors have adequate cross-
sectional area for rated current consumption of the 
equipment 
2 x 0.75mm
2
 P 
16.3 
a) Flexible cords not complying with 16.1, used for 
interconnections between separate units of 
equipment used in combination and carrying 
hazardous live voltages, have adequate dielectric 
strength 
 N 
 
b) Flexible cords not complying with 16.1, 
withstand bending and mechanical stress (3.2 of 
IEC 60227-2) 
 N 
16.4 
Flexible cords used for connection between 
equipment have adequate cross-sectional areas to 
avoid temperature rise under normal and fault 
conditions 
 N 
16.5 
Adequate strain relief on external flexible cords 
Strain relief bushing under 
compression 
 
Not possible to push cord back into equipment 
 
 
Strain relief device unlikely to damage flexible cord  
 
For mains cords of Class 
Ι equipment, hazardous 
live conductors become taut before earth 
conductor 
 N 
16.6 
Apertures for external flexible cord: no risk of 
damage to the cord during assembly or movement 
in use 
 P 
16.7 
Transportable musical instruments and amplifiers 
fitted with detachable cord set with appliance inlet 
to IEC 60320-1 
 N 
 
Transportable musical instruments and amplifiers 
fitted with detachable cord sets or with means of 
stowage to protect the cord 
 N 
 
Page of 46
Display

Click on the first or last page to see other SCS 145 Sub service manuals if exist.