SCS 145 Sub - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL SCS 145 Sub EMC - CB Certificate online

 
 
page 12 of 32 
Ref.No.:407362  
IEC 60065 
Clause 
Requirement - Test 
Result - Remark 
Verdict 
 
 
TRF No.: I60065__C 
 
14.5.2.1 
Fuse-links in the mains circuit according to 
IEC 60127 
 P 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : Fuse T1.25A L  250V 
14.5.2.3 
Not possible to connect fuses in parallel ............... :  
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  ........ :
Tools are required 
14.5.3 
PTC-S thermistors comply with IEC 60738 
 
 
PTC-S devices (15 W) category FV 1 or better 
 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 N 
14.6 
Switches 
     
 
(See list of critical components) 
14.6.1 Permanently 
connected 
equipment 
provided 
with 
an all-pole mains switch unless 5.4.2 is met 
 N 
14.6.2 
Manually operated mechanical switch (MOMS), 
required where power consumption > 15 W and/or 
peak voltage > 4 kV; MOMS required ................... :
Yes  
 
Switch readily accessible and not in mains cord 
On rear panel (Accepted for 
this product group) 
 Exception 
for 
automatic 
switching 
 
 
Exception for continuous operation 
 
14.6.3 
Manually operated mechanical switch (MOMS): 
switch indication On position clearly discernible 
Green LED illuminates 
 
Indication by marking meets Cl. 5 
POWER 
 Indication 
of 
the 
OFF 
position 
 
14.6.4 
Manually operated mechanical switch (MOMS) 
fitted, is there a Stand-by mode  ............................ :
No Noted 
 
Stand-by mode clearly discernible  ........................ : Green LED illuminates 
 
Exception for low Stand-by current < 0.7 mA 
(peak) 
 N 
14.6.5 
Components bridging contacts of mains switches 
comply with 14.1 a) or 14.2.2 
 P 
14.6.6 
Manually operated mechanical switches (MOMS) 
separately approved to IEC 61058-1 
Current consumption: 0.35A 
Peak surge current 
(measured): 18A 
 
Manually operated mechanical switch (MOMS) 
tested as part of the equipment complies with 
14.6.7, 14.6.10 and 20.1.4 and meets 14.6.8 
and/or 14.6.9 and Annex G (G1.1) 
 N 
Page of 46