Read JBL SB 300 (serv.man6) EMC - CB Certificate online
Neutron Engineering Inc.
Report No.: NEI-EMC-1-1009C113 Page 16 of 97
4.1.6 BLOCK DIAGRAM OF TEST SETUP
EUT-1
L.I.S.N.#1
Test Receiver
DVD
AC
Mains
Audio Cable
EUT-2
L.I.S.N.#2
AC
Mains
Remote
Fiber Cable
4.1.7 EUT OPERATING CONDITIONS
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
standard test signals and output signal as following:
1. Input signal: A sinusoidal signal at 1kHz.
2. Output signal: The audio output signal shall be adjusted by the volume control to be 1/8 of the
rated output power for each output
This operating condition was tested and used to collect the included data.
The EUT exercise program used during radiated and/or conducted emission measurement was
designed to exercise the various system components in a manner similar to a typical use. The
standard test signals and output signal as following:
1. Input signal: A sinusoidal signal at 1kHz.
2. Output signal: The audio output signal shall be adjusted by the volume control to be 1/8 of the
rated output power for each output
This operating condition was tested and used to collect the included data.