SB 300 (serv.man6) - JBL Audio EMC - CB Certificate (repair manual). Page 14

Read JBL SB 300 (serv.man6) EMC - CB Certificate online

Neutron Engineering Inc. 
 
 
 
 
 
 
 
 
Report No.: NEI-EMC-1-1009C113                                                                                                          Page 14 of 97
 
 
 
4. EMC EMISSION TEST 
4.1 MAINS TERMINAL DISTURBANCE VOLTAGE MEASUREMENT 
4.1.1 LIMITS OF DISTURBANCE VOLTAGE AT THE MAINS TERMINALS 
 
Limit values (dB(μV) ) 
Equipment type   
Frequency Range 
MHz  
Quasi-peak 
Average  
0.15 - 0.5 
66-56 
a
 56-46
 a
 
0.5 - 5 
56 
46 
Television and sound 
receivers and 
associated equipment 
5 - 30 
60 
50 
a
 Decreasing linearly with the logarithm of the frequency. 
 
 Note: 
 
(1) The tighter limit applies at the band edges. 
 
(2) The limit of " * " marked band means the limitation decreases linearly with the 
logarithm of the frequency in the range.                                         
 
4.1.2 MEASUREMENT INSTRUMENTS LIST 
   
Item  Kind of Equipment 
Manufacturer 
Type No. 
Serial No. 
Calibrated until 
1 LISN 
EMCO  3816/2 
00052765 
May.26.2011 
2 LISN 
R&S 
ENV216 100087  May.26.2011 
3 Test 
Cable 
N/A 
C_17 
N/A 
Mar.31.2011 
EMI TEST 
RECEIVER 
R&S ESCS30 
8333641017 
May.27.2011 
5 50Ω Terminator 
SHX 
TF2-3G-A 
08122902 
May.26.2011 
 
  Remark: ” N/A” denotes No Model Name, Serial No. or No Calibration specified. 
 
  
 
 
 