SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 10

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 10 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
 
Electric shock hazard under normal operating conditions 
9.1 
Testing on the outside 
Pass 
9.1.1 
For voltages >1000 V ac or >1500 V dc complies 
with clause 13.3.1 for basic insulation  
 N/A 
9.1.1.1 
a) Open circuit voltages  
 
N/A 
 
b) Touch current measured from terminal devices 
using the network in annex D  .................................: 
Between terminal L/N and 
Enclosure/Output Terminal. 
U1: 0.270V peak maximum  
U2: 0.150V peak maximum. 
Pass 
 
c) Discharge not exceeding 45 μC  
<45 μC Pass 
 
d) Energy of discharge not exceeding 350 mJ  
 
N/A 
9.1.1.2 
Test with test finger and test probe  
No hazardous live parts are 
accessible. 
Pass 
9.1.2 
No hazardous live shafts of knobs, handles or levers   
N/A 
9.1.3 
Ventilation holes and other holes tested by means of 
4 mm x 100 mm test pin  
No ventilation. 
N/A 
9.1.4 
Terminal devices tested with 1 mm x 20 mm test pin 
(10 N); test probe D of IEC 61032  
 Pass 
 
Terminal devices tested with 1 mm x 100 mm 
straight wire (1 N); test probe D of IEC 61032  
 Pass 
9.1.5 
Pre-set controls tested with 2.5 mm x 100 mm test 
pin (10 N); test probe C of IEC 61032  
No pre-set controls. 
N/A 
9.1.6 
No shock hazard due to stored charge on withdrawal 
of the mains plug; voltage (V) after 2 s  ..................: 
25 Vdc (Standby) 
76 Vdc (Standby, with R502A 
opened), <45 μC. 
Rating of R502A, R502B, 
R502C, R502D: 2 MΩ. 
Pass 
 
If C is not greater than 0,1 μF no test needed  
 0.33
μF. 
N/A 
9.1.7 
Resistance to external forces 
 
Pass 
 
a) Test probe 11 of IEC 61032 for 10 s (50 N)  
 
Pass 
 
b) Test hook of fig. 4 for 10 s (20 N)  
 
Pass 
 
c) 30 mm diameter test tool for 5 s (100 or 250 N)  
 
N/A 
9.2 
No hazard after removing a cover by hand  
 
Pass 
 
10 Insulation 
requirements 
10.1 
Insulation resistance (MΩ) at least 2 MΩ min. after 
surge test for basic and 4 MΩ min. for reinforced 
insulation .................................................................: 
 N/A 
10.2 
Humidity treatment 48 h or 120 h ...........................:  120 h. Pass 
10.3 
Insulation resistance and dielectric strength between 
mains terminals  
See appended table of 
CL.10.3. 
Pass 
Page of 78
Display

Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.