Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Thin sheet insulation (excluding non-separable thin
sheet insulation. See 8.22)
sheet insulation. See 8.22)
N/A
Basic or supplementary insulation, at least two
layers, each meeting 10.3
layers, each meeting 10.3
N/A
Basic or supplementary insulation, three layers any
two of which meet 10.3
two of which meet 10.3
N/A
Reinforced insulation, two layers each of which meet
10.3
10.3
N/A
Reinforced insulation, three layers any two which
meet 10.3
meet 10.3
See appended Table of CL.8.8
and 8.9.
and 8.9.
Pass
8.9
Adequate insulation between internal hazardous live
conductors and accessible parts
conductors and accessible parts
See appended Table of CL.14.
Pass
Adequate insulation between internal hazardous live
parts and conductors connected to accessible parts
parts and conductors connected to accessible parts
N/A
8.10
Double insulation between conductors connected to
the mains and accessible parts.
the mains and accessible parts.
Primary: 0.4mm, PVC.
Pass
Double insulation between internal hazardous live
parts and conductors connected to accessible parts.
parts and conductors connected to accessible parts.
Secondary: dressed away from
primary.
primary.
N/A
8.11
Detaching of wires
Pass
No undue reduction of creepages or clearance
distances if wires become detached
distances if wires become detached
Pass
Vibration test carried out .........................................: No.
N/A
8.12
This clause is void
—
8.13
Adequate fastening of windows, lenses, lamp covers
etc. (pull test 20 N for 10 s)
etc. (pull test 20 N for 10 s)
N/A
8.14
Adequate fastening of covers (push/pull test 50 N for
10 s)
10 s)
N/A
8.15
No risk of damage to the insulation of internal wiring
due to hot parts or sharp edges
due to hot parts or sharp edges
No hot parts or sharp edges
around wires.
around wires.
Pass
8.16
Only special supply equipment can be used
N/A
8.17
Insulated winding wire without additional interleaved
insulation
insulation
N/A
8.18
Endurance test as required by 8.17
N/A
8.19
Disconnection from the mains
Pass
8.19.1
Disconnect device
Mains Plug.
See remark 1).
See remark 1).
Pass
All-pole switch or circuit breaker with >3mm contact
separation
separation
N/A
8.19.2
Mains switch ON indication
N/A
8.20
Switch not fitted in the mains cord
N/A
8.21
Bridging components comply with clause 14
N/A
8.22
Non-separable thin sheet material
N/A