SB 200 (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 15

Read JBL SB 200 (serv.man3) EMC - CB Certificate online

Page 15 of 70 
Report No.: 350-120155AX 
 
  
 
 
 
 
 
IEC 60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict
 
TRF No. IEC60065K 
14.4 
High voltage components  
Not provided. 
N/A 
 
High-voltage components and assemblies: U > 4 kV 
(peak) separately approved  
 N/A 
 
Component meets category V-1 of IEC 60707  
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission  
 N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission  
 N/A 
14.5 
Protective devices  
See appended table of CL.14, 
Primary Fuse: F501. 
Pass 
 
Protective devices used within their ratings  
See appended table of CL.13.
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened  
See appended table of CL.13.
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved  
Not provided. 
N/A 
 
b) Thermal cut-outs tested as part of the submission  
N/A 
14.5.1.2 
a) Thermal links separately approved  
Not provided. 
N/A 
 
b) Thermal links tested as part of the submission  
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering  
Not provided. 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127  
See appended table of CL.14.
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder  ...: 
F501: T3.15AL250V. 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel ................: 
 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool  .........: 
Not possible to replace the 
fuse without a tool. 
Pass 
14.5.3 
PTC thermistors comply with IEC 60730-1:2007 
Not provided. 
N/A 
 
PTC devices (15 W) category V-1 or better  
 
N/A 
14.5.4 Circuit 
protectors 
have adequate breaking capacity 
and their position is correctly marked  
 N/A 
14.6 
Switches  
See appended table of CL.14.
Pass 
14.6.1 a) 
Separate testing to IEC 61058-1 including: 
- 10 000 operations 
- Normal pollution suitability 
- Make and break speed independent of speed of 
  actuation 
V-0 compliance with annex G, G.1.1  
Certified power switch 
provided, complies with the 
requirements and 
characteristics.  
(See appended table 14) 
Pass 
14.6.1 b) 
Tested in the apparatus: 
 
N/A 
 
Switch controlling > 0.2A with open contact  voltage
 > 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4 
and V-0 in annex G, G.1.1  
 N/A 
 
Switch controlling > 0.2A with open contact  voltage 
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0 
in annex G, G.1.1  
 N/A 