Read JBL SB 200 (serv.man3) EMC - CB Certificate online
Page 15 of 70
Report No.: 350-120155AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
14.4
High voltage components
Not provided.
N/A
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
part of the submission
N/A
14.5
Protective devices
See appended table of CL.14,
Primary Fuse: F501.
Primary Fuse: F501.
Pass
Protective devices used within their ratings
See appended table of CL.13.
Pass
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
requirement of clause 13 for the voltage across the
device when opened
See appended table of CL.13.
Pass
14.5.1.1
a) Thermal cut-outs separately approved
Not provided.
N/A
b) Thermal cut-outs tested as part of the submission
N/A
14.5.1.2
a) Thermal links separately approved
Not provided.
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
Not provided.
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
See appended table of CL.14.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder ...:
F501: T3.15AL250V.
Pass
14.5.2.3
Not possible to connect fuses in parallel ................:
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
replacing fuse-links without the use of a tool .........:
Not possible to replace the
fuse without a tool.
fuse without a tool.
Pass
14.5.3
PTC thermistors comply with IEC 60730-1:2007
Not provided.
N/A
PTC devices (15 W) category V-1 or better
N/A
14.5.4 Circuit
protectors
have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
See appended table of CL.14.
Pass
14.6.1 a)
Separate testing to IEC 61058-1 including:
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
- 10 000 operations
- Normal pollution suitability
- Make and break speed independent of speed of
actuation
V-0 compliance with annex G, G.1.1
Certified power switch
provided, complies with the
requirements and
characteristics.
(See appended table 14)
provided, complies with the
requirements and
characteristics.
(See appended table 14)
Pass
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
< 35 V (peak)/24 V dc complying with 14.6.3 and V-0
in annex G, G.1.1
N/A
Click on the first or last page to see other SB 200 (serv.man3) service manuals if exist.