Read JBL SB 100 (serv.man3) EMC - CB Certificate online
Page 66 of 68
Report No.: 350-120154AX
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
Replace Table 15 by the following.
RATED CURRENT
CONSUMPTION of the
apparatus
a
A
Nominal cross-sectional
area
mm
2
Up to and including 6
0.75 to 1
Over 6 up to and
including 10
including 10
1 to 1.5
Over 10 up to and
including 16
including 16
1.5 to 2.5
a
The RATED CURRENT CONSUMPTION
includes currents which can be drawn from
socket-outlets providing MAINS power for other
apparatus.
socket-outlets providing MAINS power for other
apparatus.
15.3.5
N/A
15.3.9
Add the following to the last of the first paragraph.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
N/A
15.4.1
In NOTE 1, replace IEC 60884-1 by JIS C 8282
(corresponding to IEC 60884-1).
(corresponding to IEC 60884-1).
N/A
15.4.1
In NOTE 2, replace IEC 60083 [1] by JIS C 8303.
N/A
15.4.2
In NOTE, replace IEC 60083 [1] by JIS C
8303:1993 [1].
8303:1993 [1].
N/A
15.4.3
Add the following NOTE to Table 17.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
NOTE If mains plug is parallel blade, a pull force
as given in “Over 10 A up to and including 16 A,
130/250 V” of Table 17 is applied.
N/A
16.1
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Delete NOTE 1.
Replace the second paragraph by the following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245) or Appendix 1 of
Article 1 of the Ministerial Ordinance on stipulating
technical requirements for the Electrical Appliance.
See appended table CL.14.
Pass
16.1
In this sub-clause, replace IEC 60227 by JIS C
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
3662 (corresponding to IEC 60227).
In this sub-clause, replace IEC 60245 by JIS C
3663 (corresponding to IEC 60245).
N/A