Read JBL RADIAL (serv.man3) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
8 of 50
1.2.2. Immunity Test Summary
Specification
Minimum Criterion
Level Required
as per EN 301 489-3, -1
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2:
1995/A1: 1998/A2:
2000
- ESD Immunity
1995/A1: 1998/A2:
2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast
-Electrical Fast
Transient Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV
PASS
IEC 61000-4-5: 2005
Power Line Surge
Power Line Surge
Immunity
Criterion B
Power line pulses of ± 1 kV line
to ground: ± 0.5 kV line to line
Criterion B
Power line pulses of ± 1 kV line
to ground: ± 0.5 kV line to line
PASS
IEC 61000-4-6:
2003/A1: 2004/A2:
2006
-RF Common Mode
2003/A1: 2004/A2:
2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
IEC 61000-4-11: 2004
- Voltage Dips and
- Voltage Dips and
Short Interruptions
Criterion A and C
Voltage Dips of 30% and 60%;
Interruptions of >95%.
Criterion A and C
Voltage Dips of 30% and 60%;
Interruptions of >95%.
PASS
Test Supervisor:
M. Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.