RADIAL (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 8

Read JBL RADIAL (serv.man3) EMC - CB Certificate online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
July 10, 2006 
Harman Multimedia JBL Radial CE Test Report 
2006 030095-CE Rev1 
8 of 50 
 
 
1.2.2.  Immunity Test Summary 
 
 
Specification 
Minimum Criterion  
Level Required  
as per EN 301 489-3, -1  
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2: 
1995/A1: 1998/A2: 
2000  
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS 
IEC 61000-4-3: 2006 -
Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
PASS 
IEC 61000-4-4: 2004 
-Electrical Fast 
Transient Immunity 
Criterion B 
Power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV 
 
 
PASS 
IEC 61000-4-5: 2005 
Power Line Surge 
Immunity 
Criterion B 
Power line pulses of ± 1 kV line 
to ground: ± 0.5 kV line to line 
Criterion B 
Power line pulses of ± 1 kV line 
to ground: ± 0.5 kV line to line 
PASS 
IEC 61000-4-6: 
2003/A1: 2004/A2: 
2006 
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
PASS 
IEC 61000-4-11: 2004 
- Voltage Dips and 
Short Interruptions 
Criterion A and C 
Voltage Dips of 30% and 60%; 
Interruptions of >95%. 
Criterion A and C 
Voltage Dips of 30% and 60%; 
Interruptions of >95%. 
PASS 
 
 
 
Test Supervisor
 
M. Krumweide, Nemko USA, Inc. 
Refer to the test results section for further details