Read JBL RADIAL (serv.man3) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
July 10, 2006
Harman Multimedia JBL Radial CE Test Report
2006 030095-CE Rev1
7 of 50
Test Specifications Continued:
Power Line Surge
Immunity
Immunity
IEC 61000-4-5: 2005
Electromagnetic Compatibility, Power Line Surge
Immunity
Immunity
RF Common Mode
Immunity
Immunity
IEC 61000-4-6:
2003/A1: 2004/A2:
2006
2003/A1: 2004/A2:
2006
Electromagnetic Compatibility - Basic Immunity Standard -
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Conducted Disturbances Induced By Radio-Frequency
Fields - Immunity Test
Voltage Dips and Short
Interruptions Immunity
Interruptions Immunity
IEC 61000-4-11: 2004
Electromagnetic Compatibility - Testing and Measurement
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
Techniques - Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests
1.2. Test Summary
1.2.1. Emissions Test Summary
Specification
Frequency Range
Compliance Status
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B"
Conducted Emissions
2003 , Class “B"
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B
Telecom Conducted Emissions
2003 , Class “B
Telecom Conducted Emissions
0.15 MHz – 30 MHz
Not Applicable
EN 55022: 1998/A1: 2000/A2:
2003 , Class “B
Radiated Emissions
2003 , Class “B
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2: 2000/A1:
2001/A2: 2005
Power Line Harmonics
up to the 40
th
Harmonic
PASS
EN 61000-3-3: 1995/A1: 2001
Power Line Flicker
less than or equal to
4% Maximum Relative
Voltage Change; Value of D(T)
less than or equal
to
3% for more than 200 Ms
PASS
Test Supervisor:
M. Krumweide, Nemko USA, Inc.
Click on the first or last page to see other RADIAL (serv.man3) service manuals if exist.