Clause
Requirement - Test
Result - Remark
Ver-dict
U.2.4
Replacement:
Replace the third paragraph describing the test voltage
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
with the following.
The test voltage shall not be less than the appropriate
voltage in table 5B (see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
It is applied between the shot and the conductor.
N/A
U.3.1
Replacement:
Replace with the following.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
The test voltage for ROUTINE TESTING shall be the
appropriate voltage in table 5B (see 5.2.2) of this
standard. Howeve, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V r.m.s. or 2100 V peak, or;
- for REINFORCED INSULATION, 3000 V r.m.s. or
4200 V peak.
N/A
U.3.2
Replacement:
Replace with the following.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
Twisted pair samples shall be tested in accordance
with IEC 60851-5:1996, 4.4.1. The minimum
breakdown voltage shall not be less than twice the
appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shallbe as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V r.m.s. or 4200 V peak, or;
- for REINFORCED INSULATION, 6000 V r.m.s. or
8400 V peak.
N/A