Read JBL ON TOUR XTB (serv.man8) EMC - CB Certificate online
IEC 60950 3rd Ed., 1999.
- Page 5 of 6 -
www.nemko.com
Report No. 111547
Clause
Requirement - Test
Result - Remark
Ver-dict
U.2.1
Replacement:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
Electric strength
The test sample is prepared according to IEC 60851-
5:1997, 4.4.1 (for a twisted pair). The sample is then
subjected to the test of 5.2.2 of this standard, with a
test voltage not less than twice the appropriate voltage
in table 5B (see 5.2.2) of this standard. However, the
minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 3000 V, or;
INSULATION, 3000 V, or;
- for REINFORCED INSULATION, 6000 V.
N/A
U.2.2
Replacement:
Flexibility and adherence
Flexibility and adherence
Test 8 of IEC 60851-3:1996, 5.1.1, using the mandrel
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
diameters of table U.1. The test sample is then
examined in accordance with IEC 60851-3:1996,
5.1.1.4, followed by the test of 5.2.2 of this standard
except applying the test voltage between the wire and
the mandrel. A test voltage shall not be less than twice
the appropriate voltage in table 5B (see 5.2.2) of this
standard. However, the minimum values shall be as
follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
INSULATION, 1500 V, or;
- for REINFORCED INSULATION, 3000 V.
NOTE: “twice” in the 6
th
line is deleted – ref.
confirmation by Japan NCB – JQA.
N/A
Table U.1
Replacement:
Mandrel diameter
Mandrel diameter
The tension to be applied to the wire during winding on
the mandrel is calculated from the wire diameter to be
equivalent to 118 Mpa ± 10 % (118 N/mm2 ± 10 %).
N/A
U.2.3
Replacement:
Replace the first paragraph with the following.
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
Test 9 of IEC 60851-6:1996, followed by the electric
strength test of 5.2.2 of this standard except applying
the test voltage between the wire and the mandrel. A
test voltage shall be the appropriate voltage in table 5B
(see 5.2.2) of this standard.
However, the minimum values shall be as follows:
- for BASIC INSULATION or SUPPLEMENTARY
INSULATION, 1500 V, or;
for REINFORCED INSULATION 3000 V
N/A