Read JBL ON TOUR XT (serv.man3) EMC - CB Certificate online
EMC Report for Harman Model JBL On Tour XT
File: 3109671LAX-009 Revision 1
File: 3109671LAX-009 Revision 1
Page 13 of 27
4.2.3
Conducted Emissions Test Data
Standard:
CISPR
13
Measurement
Uncertainty:
2.6dB
Company: Harman Multimedia Consumer Group
Temperature: 24°C
Job Number: 3109671LAX-009
Relative Humidity: 49%
Model: JBL On Tour XT
100 VAC 50 Hz:
Neutral Conductor Measurement:
100 VAC 50 Hz:
Neutral Conductor Measurement:
Frequency Peak AV
Limit Margin
MHz (dBuV) (dBuV) (dBuV)
0.150 50.8 56.0 -5.2
0.170 48.8 55.0 -6.2
0.180 47.5 54.7 -7.2
0.190 44.9 54.0 -9.1
0.210 46.3 53.4 -7.1
6.230 44.9 50.0 -5.1
Line Conductor Measurement:
Frequency Peak AV
Limit Margin
MHz (dBuV) (dBuV) (dBuV)
0.150 49.8 56.0 -6.2
0.170 48.2 55.0 -6.8
0.180 46.7 54.7 -8.0
0.190 47.7 54.0 -6.3
0.210 46.4 53.4 -7.0
6.230 46.4 50.0 -3.6