4.2 Conducted Emissions Measurements
4.2.1
4.2.1
Site and Test Description
The test facility is a specially designed and constructed by using a metallic wall as the vertical coupling
plane. One test site is used for CISPR and FCC testing.
All conducted voltage measurements are made on each current-carrying conductor at the plug end of the
EUT power cord or calibrated extension by the use of mating plugs and receptacles on the EUT and
LISN/AMN if used. Equipment is tested with power cords that are normally used or that have electrical
and shielding characteristics that are the same as those cords normally used. For those measurements
using a LISN/AMN, the 50
Ω measuring port is terminated by a 50 Ω receiver or a 50 Ω resistive load.
Hence all 50
Ω measuring ports of the LISN/AMN are terminated by 50 Ω.
If a screened room or chamber is used, the EUT is placed 40 cm from a conductive wall, with the wall at
the lead of the EUT. IF the test is being performed on an OATS or sheltered site, the vertical ground
plane is placed 40 cm away from the rear of the EUT.
The mains lead shell be arranged to follow shortest possible part between the EUT and Artificial Mains
Network on the ground. The excess length of the lead between the EUT and the LISN/AMN receptacle
(or mains outlet where a LISN/AMN cannot be used) is folded back and forth at the center of the lead to
form a bundle not exceeding 40 cm in length. If the EUT does not have a flexible power lead, then it is
placed at a distance of 80 cm from the LISN/AMN (or mains outlet where a LISN/AMN cannot be used)
and connected to it by a lead or appropriate connection no longer than 1 m. Measurements are made at
the LISN/AMN end of this lead or connection.