Read JBL ON TOUR (serv.man6) EMC - CB Certificate online
- Page 3 of 17 -
Order No. 23172
SUMMARY OF TESTING :
Sub-clause
Information/Remarks
Comments
1.2.02.01
Normal load as described in Annex L or as close
as possible to the most severe normal use
as possible to the most severe normal use
Normal operation is considered 1/8
th
of maximum
undistorted. Non-clipping was determined using a
1 KHz sinusoidal signal input. For maximum
normal operation, 1/8
1 KHz sinusoidal signal input. For maximum
normal operation, 1/8
th
of the non-clipping
amplitude was used with a filtered pink noise input
signal.
signal.
1.7.1
Required markings regarding supply.
Class III Equipment with an enclosure made of
HB-Material, using a non-special connector for the
DC input must have a marking stating the
manufacturer and model number of the power
supply to be used.
HB-Material, using a non-special connector for the
DC input must have a marking stating the
manufacturer and model number of the power
supply to be used.
1.7.14
Language of safety markings /instruction.
Instructions and equipment marking related to
safety shall be applied in a language, which is
acceptable in the country in which the equipment
is to be sold.
safety shall be applied in a language, which is
acceptable in the country in which the equipment
is to be sold.
3.2
Connection to the supply.
Unit is powered by a limited power source
complying with Sub-clause 2.11. Connection is
made by a detachable power supply cord with a
non-special type connector. The external power
supply was not evaluated in this test report.
complying with Sub-clause 2.11. Connection is
made by a detachable power supply cord with a
non-special type connector. The external power
supply was not evaluated in this test report.