May 13, 2004
Harman Multimedia JBL Ontour EMC
Test Report
2004 040110 CFV Rev 1
10 of 80
3. DESCRIPTION OF TEST SITE AND EQUIPMENT
3.1. Description of Test Site
The test site is located at 11696 Sorrento Valley Road, Suite F, San Diego, CA 92121. The site is physically
Ocean. This particular part of the valley tends to minimize ambient levels, i.e. radio and TV broadcast stations
and land mobile communications. The three and ten-meter Open Area Test Site (OATS) is located behind the
office/lab building. It conforms to the normalized site attenuation limits and construction specifications as set
in the EN 55022 (1998)A1, CISPR 16 (2003) and ANSI C63.4 (2001) documents. The OATS normalized site
attenuation characteristics are verified for compliance every year.
4. DESCRIPTION OF TESTING METHODS
4.1. Introduction
Nemko USA, Inc. is accredited to ISO/IEC 17025 by the National Voluntary Laboratory Accreditation Program
(NVLAP) for Electromagnetic Compatibility and Telecommunications testing. Part of the accreditation process
involves the demonstration of competence in various test methods.
Prior to the beginning of work, Nemko personnel work with their clients to ensure the proper test standards and
test methods are utilized. Applicable tests and the minimum criteria for a pass condition are listed in the
administrative section of this report.