Read JBL ON TOUR (serv.man11) EMC - CB Certificate online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
May 13, 2004
Harman Multimedia JBL Ontour EMC
Test Report
2004 040110 CFV Rev 1
6 of 80
1. ADMINISTRATIVE DATA AND TEST SUMMARY
1.1. Administrative Data
CLIENT:
CONTACT:
Bruce Ryan
DATE (S) OF TEST:
March 30, 2004 to April 9, 2004
EQUIPMENT UNDER TEST (EUT):
Speaker System
Model
JBL Ontour
Condition Upon Receipt
Suitable for Test
1.2. Test Summary
1.2.1.
Emissions Test Summary
Test Methods
Frequency Range
Compliance Status
FCC 15B, Sec. 107, Class “B ”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
FCC 15B, Sec. 109, Class “B”
Radiated Emissions
30 MHz –1000MHz
PASS
VCCI, V-3/97.04, Class “B”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
VCCI, V-3/97.04, Class “B”
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 55022 (1998)A1, Class “B”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022 (1998)A1, Class “B”
Telecom Conducted Emissions
0.15 MHz – 30 MHz
N/A
EN 55022 (1998)A1, Class “B”
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2 (2000)
Power Line Harmonics
up to the 40
th
Harmonic
PASS
EN 61000-3-3 (1995)
Power Line Flicker
less than or equal to 4% Maximum Relative Voltage
Change; Value of D(T) less than or equal to 3% for
Change; Value of D(T) less than or equal to 3% for
more than 200 Ms
PASS
Test Supervisor:
R. L. Hill, Nemko USA, Inc.
Click on the first or last page to see other ON TOUR (serv.man11) service manuals if exist.