ON STAGEII (serv.man18) - JBL Audio EMC - CB Certificate (repair manual). Page 16

Read JBL ON STAGEII (serv.man18) EMC - CB Certificate online

 
 
- Page 16 of 52 - 
 
 
www.nemko.com
 
Report No.  46974 
 
 
TRF No.:IECEN60950_1B 
 
IEC 60950-1 / EN 60950-1 
Clause 
Requirement – Test  
Result – Remark  
Verdict 
2.7.6 
Warning to service persons  ...............................:   
— 
 
2.8 Safety 
interlocks 
N/A 
2.8.1 
General principles 
No safety interlocks. 
— 
2.8.2 Protection 
requirements 
 
— 
2.8.3 Inadvertent 
reactivation 
 
— 
2.8.4 Fail-safe 
operation 
 
— 
2.8.5 Moving 
parts 
 
— 
2.8.6 Overriding 
 
 
— 
2.8.7 
Switches and relays  
 
— 
2.8.7.1 
Contact gaps (mm) ............................................. :   
— 
2.8.7.2 Overload 
test 
 
— 
2.8.7.3 Endurance 
test 
 
— 
2.8.7.4 
Electric strength test  
 
— 
2.8.8 Mechanical 
actuators 
 
— 
 
2.9 Electrical 
insulation 
— 
2.9.1 
Properties of insulating materials 
Class III equipment, only 
functional insulation provided. 
Refer also to clause 5.3.4. 
N/A 
2.9.2 
Humidity conditioning 
No test considered necessary. 
N/A 
 Humidity 
(%) 
.......................................................: 
 
— 
 
Temperature (
°C) ...............................................:   
— 
2.9.3 
Grade of insulation 
Insulation is considered to be 
functional insulation, and 
complies with clause 5.3.4 c). 
 
2.10 
Clearances, creepage distances and distances through insulation 
 
2.10.1 
General  
Equipment is class III powered 
from a secondary (SELV) circuit 
of a PSU. Only functional 
insulation is considered. 
2.10.2 
Determination of working voltage 
Class III equipment. 
N/A 
2.10.3 
Clearances 
Class III equipment. 
N/A 
2.10.3.1 General 
Refer 
below: 
 
2.10.3.2 
Clearances in primary circuits 
Class III equipment. 
N/A 
Page of 77
Display

Click on the first or last page to see other ON STAGEII (serv.man18) service manuals if exist.