ON STAGE (serv.man3) - JBL Audio EMC - CB Certificate (repair manual). Page 51

Read JBL ON STAGE (serv.man3) EMC - CB Certificate online

IEC 60950 3rd. Ed, 1999 
- Page 1 of 5 - 
 
 
 
 
Order No.  23171 
 
APPENDIX: US DEVIATIONS 
Test results according to CB BULLETIN No. 105A, May 2003.
 
 
Clause  
Requirement - Test 
Result - Remark 
Ver-
dict 
 
The United States of America and Canada have adopted a single, bi-
national standard, CAN/CSA C22.2 No. 60950/UL60950, Third Edition, 
based on IEC 60950, Third Edition 
— 
 
The following is a summary of the key national differences based on 
national regulatory requirements, such as the National Electrical Code 
(NEC) ANSI/ NFPA 70-1999, which are referenced in legislation and 
which form the basis for the rules and practices followed in the 
electrical and building installations. The bi-national standard referenced 
above should be consulted for further details on the national differences 
summarized below.
 
— 
1.1.1  
All equipment is to be designed to allow 
installations in accordance with the National 
Electrical Code (NEC), ANSI/NFPA 70, and, 
unless marked or otherwise identified, the 
standard for the Protection of Electronic 
Computer/Data-Processing Equipment, 
ANSI/NFPA 75.  
Class III equipment. 
1.5.5  
For lengths exceeding 3.05 m, external 
interconnecting flexible cord and cable 
assemblies are required to be a suitable cable 
type (e.g. DP, CL2) specified in  the NEC.  
For length 3.05m or less, external 
interconnecting flexible cord and cable 
assemblies which are not types specified in the 
NEC are required to have special construction 
features and identification markings. 
Class III equipment. 
1.7.1  
Equipment for use on supply systems with a 
neutral and more than one phase conductor 
(e.g. 120/240 V, 3-wire) require a special 
marking format for electrical ratings.  
A voltage rating that exceeds an attachment 
plug cap rating is only permitted if it does not 
exceed the extreme operating conditions in 
Table 2 of CAN/CSA C22.2 No. 235, and if it is 
part of a range that extends into the Table 2 
“Normal Operating Conditions”. Likewise, a 
voltage rating shall not be lower than the 
specified “Normal Operating Conditions”, 
unless it is part of a range that extends into the 
“Normal Operating Conditions”.  
Class III equipment. 
2.5  
Where a fuse is used to provide Class 2, 
Limited Power Source (or TNV) current 
limiting, it shall not be operator-accessible 
unless it is  not interchangeable.  
No such fuse provided. 
Page of 55