Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online
Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439 page 46 of 66
13.4.Severity Levels and Performance Criterion
13.4.1.Severity level
Level
Magnetic Field Strength A/m
1.
1
2.
3
3.
10
4.
30
5.
100
X. Special
13.4.2.Performance criterion : A
13.5.EUT Configuration on Test
The configuration of EUT are listed in Section 3.5.
13.6.Operating Condition of EUT
Same as Conducted Emission test which is listed in Section 4.6. except the test set up
replaced by Section 13.2.
replaced by Section 13.2.
13.7.Test Procedure
The EUT was subjected to the test magnetic field by using the induction coil of
standard dimensions (1m*1m) and shown in Section 13.2. The induction coil was
then rotated by 90°in order to expose the EUT to the test field with different
orientations.
then rotated by 90°in order to expose the EUT to the test field with different
orientations.
13.8.Test Results
PASS.
The EUT was tested and all the test results are listed in next page.
The EUT was tested and all the test results are listed in next page.
Click on the first or last page to see other ON STAGE III IIIP (serv.man7) service manuals if exist.