ON STAGE III IIIP (serv.man7) - JBL Audio EMC - CB Certificate (repair manual). Page 46

Read JBL ON STAGE III IIIP (serv.man7) EMC - CB Certificate online

   
                                   Audix Technology (Shenzhen) Co., Ltd. Report No. ACS-E07439      page 46 of 66 
 
 
13.4.Severity Levels and Performance Criterion 
13.4.1.Severity level 
Level 
Magnetic Field Strength A/m 
1.  
2.  
3.  
10 
4.  
30 
5.  
100 
X. Special 
13.4.2.Performance criterion : A 
13.5.EUT Configuration on Test 
The configuration of EUT are listed in Section 3.5. 
13.6.Operating Condition of EUT 
Same as Conducted Emission test which is listed in Section 4.6. except the test set up 
replaced by Section 13.2. 
13.7.Test Procedure 
The EUT was subjected to the test magnetic field by using the induction coil of 
standard dimensions (1m*1m) and shown in Section 13.2. The induction coil was 
then  rotated by 90°in order to expose the EUT to the test field with different 
orientations. 
13.8.Test Results 
PASS. 
 
The EUT was tested and all the test results are listed in next page. 
Page of 66