Read JBL ON STAGE 200ID EMC - CB Certificate online
- Page 43 of 63 -
Report
No.
98323
IEC 60950-1:2005 / EN 60950-1:2006
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IECEN60950_1C
1.7.2.1
In Finland, Norway and Sweden, CLASS I PLUGGABLE EQUIPMENT TYPE A
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
intended for connection to other equipment or a network shall, if safety relies on
connection to protective earth or if surge suppressors are connected between the
network terminals and accessible parts, have a marking stating that the equipment
must be connected to an earthed mains socket-outlet.
The marking text in the applicable countries shall be as follows:
In Finland: "Laite on liitettävä suojamaadoituskoskettimilla varustettuun
pistorasiaan"
In Norway: “Apparatet må tilkoples jordet stikkontakt”
In Sweden: “Apparaten skall anslutas till jordat uttag”
N
1.7.5
In Denmark, socket-outlets for providing power to other equipment shall be in
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard
Sheet DK 1-1b or DK 1-5a.
accordance with the Heavy Current Regulations, Section 107-2-D1, Standard
Sheet DK 1-3a, DK 1-5a or DK 1-7a, when used on Class I equipment. For
STATIONARY EQUIPMENT the socket-outlet shall be in accordance with Standard
Sheet DK 1-1b or DK 1-5a.
N
2.2.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N
2.3.2
In Finland, Norway and Sweden there are additional requirements for the
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
insulation. See 6.1.2.1 and 6.1.2.2 of this annex.
N
2.3.4
In Norway, for requirements see 1.7.2.1, 6.1.2.1 and 6.1.2.2 of this annex.
N
2.6.3.3
In the United Kingdom, the current rating of the circuit shall be taken as 13 A, not
16 A.
16 A.
N
2.7.1
In the United Kingdom, to protect against excessive currents and short-circuits in
the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3
shall be conducted, using an external protective device rated 30 A or 32 A. If these
tests fail, suitable protective devices shall be included as integral parts of the
DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met.
the PRIMARY CIRCUIT of DIRECT PLUG-IN EQUIPMENT, tests according to 5.3
shall be conducted, using an external protective device rated 30 A or 32 A. If these
tests fail, suitable protective devices shall be included as integral parts of the
DIRECT PLUG-IN EQUIPMENT, so that the requirements of 5.3 are met.
N
2.10.5.13
In Finland, Norway and Sweden, there are additional requirements for the
insulation, see 6.1.2.1 and 6.1.2.2 of this annex.
insulation, see 6.1.2.1 and 6.1.2.2 of this annex.
N