11 Surge
Immunity
11.1 Standard
Basic standard
EN 61000-4-5:2006
Date of testing
2008-09-02
Performance criteria:
B
11.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
Immunity simulator
February 25,
2008
2008
UCS5500M4
SB3070
EMTEST
Three Phase Coupling
Network
February 25,
2008
2008
CNI5036 SB3070/01
EMTEST
11.3 Test set-up
See annex B
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
The EUT and the auxiliary equipment were placed on a table of 0.8m heights above a metal ground
reference plane. The size of ground plane is greater than 1m×1m and project beyond the EUT by at
least 0.1m on all sides. The ground plane is connected to the protective earth. The length of power
cord between the coupling device and the EUT was less than 2 meters (provided by the
manufacturer).
The surge noise shall be applied synchronized to the voltage phase at 0
o
,90
o
,180
o
,270
o
and the peak
value of the a.c. voltage wave. (Positive and negative).
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
Each of Line-Line is impressed with a sequence of five surge voltages with interval of 1 min.
11.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
016
Tr/Th 1,2/50(8/20)
μs
Line to line 1kV
Line to Gnd 2kV
Repetition frequency 5kHz
Test to input a.c. power port
(Signal port can not directly
connect to outdoor cable)
connect to outdoor cable)
Pass
11.5 Table
11.5.1 Table 016
Injected
Line
Wave
Form
Voltage
(kV)
Phase
Number of
Pulse
Interval
time
Result
+1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass
L-N
1.2/50μs
-1
0
o
,90
o
, 180
o
,270
o
20 60s
Pass