10 Electrical
Fast
Transients/Bursts Immunity
10.1 Standard
Basic standard
EN 61000-4-4:2004
Date of testing
2008-09-02
Performance criteria:
B
10.2 Measurement equipment
Equipment
Last Calibration
Type
Serial No
.
Manufacturer
EFT simulator
February 25,
2008
2008
NSG2025-1 SB2556 SCHNAFFNER
10.3 Test set-up
See annex B
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
The EUT is placed on a table that is 0.8meter height. A ground reference plane is placed on the table,
and uses a 0.1m insulation between the EUT and ground reference plane.
The minimum area of the ground reference plane is 1m*1m, and projected beyond the EUT by at least
0.1m on all sides.
Test on power supply ports:
The duration time of each test sequential was 1 minute.
The length of the signal and power lines between the coupling device and the EUT is 0.5m.
10.4 Test results
Mode
Table
Remarks
Result
TM1
&TM2
015
±
1KV
Tr/Th: 5/50ns
Repetition frequency:5kHz
Test to input a.c. power port
(Signal port cable is less than 3m)
Pass
10.5 Table
10.5.1 Table 015
Injected Line
Voltage
(kV)
Duration time
(s)
Injected Method
Result
+1 60
Direct
Pass
L
-1 60
Direct
Pass
+1 60
Direct
Pass
N
-1 60
Direct
Pass
+1 60
Direct
Pass
L,N
-1 60
Direct
Pass